Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38471643

RESUMO

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Assuntos
Cardiomiopatia Hipertrófica , Implante de Prótese de Valva Cardíaca , Miotomia , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Cateterismo Cardíaco/métodos , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Resultado do Tratamento , Cardiomiopatia Hipertrófica/complicações , Miotomia/efeitos adversos
2.
JACC Cardiovasc Interv ; 17(5): 635-644, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38244000

RESUMO

BACKGROUND: Transcatheter closure of transcatheter heart valve (THV)-related paravalvular leak (PVL) is associated with a high failure rate with available devices due to the complex interaction of THV and aortic/mitral annulus. OBJECTIVES: This study reports on novel transcatheter techniques to treat PVL after THV. METHODS: The authors describe consecutive patients who underwent PVL closure after transcatheter aortic valve replacement (TAVR) or transcatheter mitral valve replacement (TMVR). A covered self-expanding stent (Viabahn) was deployed in the defect to create a seal between the THV and annulus. A vascular plug (Amplatzer Vascular Plug 2 [AVP2] or AVP4) was then deployed inside the covered stent to obliterate PVL. RESULTS: Eight patients with THV-related PVL were treated using this method (aortic [3 SAPIEN, 1 Evolut], mitral [2 SAPIEN-in-MAC (mitral annular calcification), 2 M3 TMVR). Various combinations of stents and plugs were used (5 mm × 2.5 cm Viabahn + 6 mm AVP4 [n = 2], 8 mm × 2.5 cm Viabahn + 10 mm AVP2 [n = 5], and 10 mm × 5.0 cm Viabahn + 12 mm AVP2 [n = 1]). All had technical success with immediate elimination of target PVL, without in-hospital complications. None had signs of postprocedure hemolysis. All patients were discharged alive (median 3.5 days [Q1-Q3: 1.0-4.8 days]). No residual PVL was seen at discharge, except for 1 patient with mild regurgitation due to another untreated PVL location. One patient died before 30 days due to complication of valve-in-MAC TMVR. In remaining patients, none had recurrence of PVL at 30 days. Symptoms decreased to NYHA functional class I/II in 6 patients. NYHA functional class III symptoms remained in 1 patient with mitral regurgitation awaiting subsequent valve replacement procedure. CONCLUSIONS: The technique of sequential deployment of a covered stent and vascular plug may effectively treat THV-related PVL.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Stents , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia
3.
Catheter Cardiovasc Interv ; 103(1): 89-96, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38071427

RESUMO

BACKGROUND: This article highlights four unique cases where rotational atherectomy (RA Rotapro, Boston Scientific) was used to cut and retrieve an entrapped coronary guidewire with parts extending into the aorta We discuss the technique and step by step approach to the retrieval procedure. CASE SUMMARY: Three of four cases described a guide wire entrapment in the right coronary artery (RCA), and one in the left anterior descending artery via retrograde route. In all cases the guide wire was intact within the intracoronary segment. In Case 1, the guide wire (Runthrough; Terumo) was entrapped in an acute marginal branch during chronic total occlusion (CTO) percutaneous coronary intervention. In Case 2, a whisper wire (Abbott) was entrapped during re-wiring of the right posterolateral branch through stent struts, the traction on the wire caused severe malformation of distal and proximal stents requiring second staged procedure to complete revascularization of the RCA CTO. In Case 3, a Runthrough wire was entrapped between two layers of stents and fractured at the proximal point with filaments extending into descending aorta. And in Case 4, a Pilot 200 (Abbott) wire was entrapped retrograde in the subintimal space via saphenous vein graft connection by tying a knot at the distal tip of the wire. In all four cases RA was used to successfully cut and remove the entrapped guide wires. DISCUSSION: Rotablation technique appears to be a safe and effective strategy for the management of entrapped coronary guidewire when conventional strategies fail.


Assuntos
Aterectomia Coronária , Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Aterectomia Coronária/métodos , Angiografia Coronária , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Oclusão Coronária/terapia , Oclusão Coronária/cirurgia , Stents , Doença Crônica
4.
Catheter Cardiovasc Interv ; 102(6): 997-1003, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37890004

RESUMO

BACKGROUND: The safety and efficacy of intravascular lithotripsy (IVL) for the treatment of calcified distal left main (LM) disease remains unclear, especially compared to rotational atherectomy (RA). METHODS: We retrospectively analyzed the baseline clinical, angiographic, intravascular ultrasound (IVUS) characteristics and procedural outcomes of 107 patients who underwent distal LM percutaneous coronary intervention (PCI) with IVL (with or without adjunct atherectomy) versus RA alone for plaque modification before stenting at a single center between 2020 and 2022. RESULTS: A total of 50 patients underwent calcium modification with IVL with or without adjunct atherectomy and 57 with RA only. The mean age was 73 years and with a high prevalence of diabetes (58.9%), chronic kidney disease (42.1%), prior revascularization (coronary artery bypass graft surgery [36.4%] or prior PCI [32.7%]). Acute coronary syndrome was the primary indication for PCI in over 50% of the patients in both groups. Medina 1-1-1 LM bifurcation disease was identified in 64% and 60% of the IVL and RA groups (p = 0.64) respectively. Final minimum stent area in distal LM (>8.2 mm2 ), ostial LAD (>6.3 mm2 ) and ostial LCX (>5.0 mm2 ) were achieved in 96%, 85% and 89% of cases treated with IVL respectively and 93%, 93% and 100% of cases treated with RA respectively (LM p = 1.00; LAD p = 0.62; LCX; p = 1.00 for difference between the two groups). Procedural success (technical success without in-hospital major adverse events) was achieved in 98% of the IVL group and 86% of the RA-only group (p = 0.04). There were eight procedural complications (flow-limiting dissection, perforation, or slow/no-reflow) in the RA group compared to four in the IVL group (NS), and one patient in the RA required salvaged mechanical support compared to none in the IVL group. CONCLUSION: Plaque modification with coronary IVL appears to be efficacious and safe for the treatment of severely calcified distal LM lesions compared to RA only. Larger randomized studies are needed to confirm these findings.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Litotripsia , Intervenção Coronária Percutânea , Placa Aterosclerótica , Calcificação Vascular , Humanos , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Aterectomia Coronária/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Angiografia Coronária , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Calcificação Vascular/etiologia , Litotripsia/efeitos adversos
5.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37702135

RESUMO

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
6.
Circ Cardiovasc Interv ; 16(9): e013123, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37577788

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) in patients with a congenital or acquired abnormality resulting in enlarged right ventricular outflow tract (RVOT) is challenging and may preclude treatment with dedicated devices. We describe a technique using a physician-modified endograft to facilitate TPVR. METHODS: Six patients underwent physician-modified endograft-facilitated TPVR for severe symptomatic pulmonary insufficiency with enlarged RVOT. The fenestration was created in a commercially available endograft before implantation, which was then deployed from the dominant branch pulmonary artery into the RVOT, with the fenestration aligned with the ostium of the nondominant pulmonary artery. A covered stent was placed through the fenestration into the nondominant branch pulmonary artery, and a transcatheter heart valve was deployed within the endograft at the level of the original pulmonary valve. RESULTS: Four patients had tetralogy of Fallot, 1 had pulmonary atresia, and 1 had rheumatic valve disease. The RVOT/main pulmonary artery was severely enlarged (diameter, 44.2 [43.5-50.6] mm). All patients had reduced right ventricular (RV) function and dilated RVs (RV end-diastolic volume, 314 [235-316] mL). Successful endograft, covered stent, and transcatheter heart valve deployment were achieved in all cases without stent/valve embolization, vascular complications, or bleeding complications. At 30 days, 1 patient had mild pulmonary insufficiency, while others had none. The RV size measured by echocardiography was significantly reduced after TPVR (RV area, 34.4 [baseline] versus 29.0 [pre-discharge] versus 25.3 [30 days] cm2; P=0.03). During median follow-up of 221.5 (range, 29-652) days, there were no deaths or need for pulmonary valve reintervention. One patient developed severe tricuspid regurgitation due to entrapment of the anterior tricuspid leaflet by the endograft. The patient underwent successful tricuspid replacement and resection of the offending endograft with preservation of the pulmonary valve prosthesis. CONCLUSIONS: Simple fenestration of an off-the-shelf endograft and associated covered stent placement through the fenestration allows TPVR for patients with dysfunctional native or patch-repaired pulmonary valves and RVOT enlargement.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Cateterismo Cardíaco , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Stents/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese
8.
EuroIntervention ; 19(4): e330-e339, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37067193

RESUMO

BACKGROUND: Transcatheter aortic valve implantation in an existing transcatheter valve (redo-TAVI) pins the index valve leaflets in the open position (neoskirt), which can cause coronary flow compromise and limit access. Whether anatomy may preclude redo-TAVI in self-expanding Evolut valves is unknown. AIMS: We aimed to evaluate the anatomical feasibility of redo-TAVI by simulating implantation of a balloon-expandable SAPIEN 3 (S3) within an Evolut or an Evolut within an Evolut. METHODS: A total of 204 post-TAVI computed tomography (CT) scans from the Evolut Low Risk CT substudy were analysed. Five redo-TAVI positions were evaluated: S3-in-Evolut inflow-to-inflow, S3 outflow at Evolut nodes 4, 5, and 6, and Evolut-in-Evolut inflow-to-inflow. Univariable modelling identified pre-TAVI clinical characteristics, CT anatomical parameters, and procedural variables associated with coronary flow compromise using the neoskirt height and post-TAVI aortic root dimensions. RESULTS: The risk of coronary flow compromise was lowest when the S3 outflow was at Evolut node 4 (20%) and highest when at Evolut node 6 (75%). The highest likelihood of preserving coronary accessibility occurred with the S3 outflow at Evolut node 4. Female sex and higher body mass index were associated with a higher risk of coronary flow compromise, as were a smaller annulus diameter, lower sinus of Valsalva height and width, shorter coronary height, smaller sinotubular junction diameter, and shallower Evolut implant depth. CONCLUSIONS: The feasibility of redo-TAVI after Evolut failure is multifactorial and relates to the native annular anatomy, as well as the implantation depth of the index and second bioprostheses. Placement of an S3 at a lower Evolut position may reduce the risk of coronary flow compromise while preserving coronary access. CLINICALTRIALS: gov: NCT02701283.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Desenho de Prótese , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 100(6): 1039-1042, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36229978

RESUMO

Complex and higher-risk indicated percutaneous coronary interventions at times require mechanical circulatory support, most often with Impella devices. The use of such devices traditionally required additional arterial access site(s), increasing risk of vascular complications. The Single-access for Hi-risk percutaneous coronary intervention (SHiP) technique was described to overcome this issue but was limited to the use of 7F guides. Larger 8F guides often provide incremental support and space compared to 7F guides, sometimes needed in complex procedures. We described a modified SHiP technique using an 8 Fr guide delivered sheathless using Rotaglide.


Assuntos
Coração Auxiliar , Intervenção Coronária Percutânea , Humanos , Artéria Radial , Angiografia Coronária/métodos , Resultado do Tratamento , Desenho de Equipamento
13.
Cardiovasc Revasc Med ; 40S: 218-221, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34952823

RESUMO

Saphenous vein graft (SVG) aneurysms are rare but can be associated with significant morbidity and mortality. This case illustrates a percutaneous approach for the management of SVG aneurysm with a fistulous connection to the right atrium.


Assuntos
Aneurisma , Veia Safena , Aneurisma/diagnóstico por imagem , Aneurisma/etiologia , Aneurisma/cirurgia , Ponte de Artéria Coronária/efeitos adversos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Veia Safena/diagnóstico por imagem , Veia Safena/transplante
14.
Interv Cardiol Clin ; 11(1): 11-25, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34838294

RESUMO

Transcatheter tricuspid valve (TV) interventions have increased dramatically in recent years. TV imaging is challenging in many respects. Given the TV's anatomic complexity, multimodality imaging, which is centered on echocardiography (echo), plays a significant part in planning and execution of these interventions. With the help of echo-guided imaging, pathophysiologic mechanisms for TV disease are better understood, and thus, appropriate valve intervention can be strategized. Novel devices for the TV continue to be developed, and thus, intraprocedural echo imaging will continue to evolve in the days ahead.


Assuntos
Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Ecocardiografia , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
15.
Ann Cardiothorac Surg ; 10(5): 605-620, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34733688

RESUMO

Valve-in-valve (ViV) transcatheter procedures are the preferred option for redo valve replacement in patients who otherwise would be high risk for surgery. Transesophageal echocardiography (TEE) is an integral imaging modality for both peri-procedural and intra-procedural guidance during transcatheter ViV replacement. When intentional leaflet laceration is needed, such as with the BASILICA (Bioprosthetic or native Aortic Scallop Intentional Laceration to prevent Iatrogenic Coronary Artery obstructions during TAVR) or LAMPOON (Laceration of the Anterior Mitral valve leaflet to Prevent left ventricular Outlet ObstructioN) procedures, TEE is critical to proper guidewire positioning and achieving a successful laceration. In this paper we detail the role of TEE in ViV transcatheter valve replacement in patients with prior surgical aortic, mitral, tricuspid, and pulmonic valves.

16.
Interv Cardiol Clin ; 10(4): 565-578, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34593118

RESUMO

Transcatheter aortic valve replacement (TAVR) is now the dominant form of aortic valve replacement in the United States. Continued innovation has allowed the technique to be safe and democratized. New advances will increase the number of patients eligible to receive this therapy while increasing safety and efficiency. Herein, the authors review new TAVR technologies, approaches to valve deployment, and dedicated devices for cerebral embolic protection and vascular closure.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/cirurgia , Humanos , Tecnologia , Resultado do Tratamento , Estados Unidos
17.
Catheter Cardiovasc Interv ; 97(1): E161-E167, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32569445

RESUMO

OBJECTIVES: To understand the predictors of survival and indications for Impella RP in a single healthcare experience. BACKGROUND: The Impella RP can be used to temporarily support patients with right ventricular (RV) dysfunction after left ventricular assist device (LVAD) placement or myocardial infarction (MI). However, recent postmarket approval data have raised concerns of higher than expected mortality with this device. METHODS: A retrospective chart review and analysis of all patients that underwent Impella RP placement in the Emory Healthcare system between January 2016 and December 2018 were performed. Patients were classified according to the indication. RESULTS: A total of 39 patients underwent Impella RP placement. Six patients were post-LVAD, 9 were implanted for massive pulmonary embolism with persistent shock, 8 for postcardiac surgery RV failure (non-LVAD), 11 for RV failure post-MI, and 5 for new or worsening nonischemic cardiomyopathy. The worst survival was noted in MI-related cardiogenic shock group and in patients who presented with cardiac arrest (3/12). All observed deaths were due to persistent refractory shock. There was no device related death. Survival improved during the last year of experience compared to the first 2 years. CONCLUSION: This study supports the selective use of the Impella RP, with a higher than national reported survival rate (49% vs. 28.6%). Indication appears to be an important factor determining survival.


Assuntos
Coração Auxiliar , Atenção à Saúde , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
18.
JACC Case Rep ; 1(5): 781-786, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-34316931

RESUMO

This case illustrates a novel percutaneous treatment of a highly vascular thoracic tumor impinging on the left atrium and right pulmonary artery by delivery of coils and alcohol ablation via a circumflex coronary artery feeder branch. (Level of Difficulty: Advanced.).

19.
Curr Pharm Des ; 22(25): 3853-70, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27194439

RESUMO

BACKGROUND: Psychosocial risk factors such as stress and psychiatric disorders are known to have negative impacts on health outcomes, but their effects on ischemic heart disease, particularly in women, remain to be fully understood despite contributing to one-third of the population attributable risk in acute myocardial infarction. METHODS: The impact of stress, social isolation, low socioeconomic status, hostility and anger, and stress-related psychiatric disorders on cardiovascular outcomes and the potential mechanisms that underlie their association with ischemic heart disease, with a focus on women, is evaluated. Online search of relevant terms, including the aforementioned risk factors, women, and ischemic heart disease, was utilized to find recent and pertinent trials. RESULTS: Psychosocial risk factors increase cardiovascular risk in both women and men. However, current literature points to a greater degree of adverse cardiovascular events in women who experience these risk factors than in men, but the literature is not as well-defined as the data regarding traditional risk factors and cardiovascular disease. CONCLUSION: Dedicated study of the sex differences in ischemic heart disease incidence and recurrence, including the impact of psychosocial risk factors, is warranted for the development of appropriate gender-specific diagnostic testing and treatment options in heart disease.


Assuntos
Infarto do Miocárdio/psicologia , Feminino , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...